Eligibility criteria Enamel Reactor

2011-05-24

1, operating normally, the performance is good:

a, equipment design requirements to achieve production capacity of more than 90%;

b, with pressure reactor pressure vessel is required to obtain license:

c, mechanical drive no noise, mixers and equipment within the heating coil, the pressure tube should be no collision of the internal parts of the gap left in accordance with regulations;

d, device is working properly, no abnormal vibration;

e, reducer temperature is normal, bearing temperature should meet the requirements;

f, oiled, oil quality compliance, the oil level is normal;

g, shaft seal and the reducer, pipe, fittings, valves, one (hand) hole, flange leakage.

2, no damage to internal parts, the quality to meet the requirements:

a, kettle body, seals, mixers, and other major parts inside and outside the coil material selected in line drawings;

b, kettle body, seals, mixers, and other major parts inside and outside the coil installation with, wear, corrosion, inspection procedures should be consistent with the provisions of the limit;

c, autoclave liner does not leak, do not drum kits, reliable fastening device within the coil.

Content disclaimer: If there is any copyright issue involved in the content, please contact us to delete it.